Controlling the climatic conditions of data centers is of extreme importance
for the operation of servers and the optimization of the consumption of
installations. Reliable and precise, our measuring instruments ensure the
permanent availability of these computer systems.
Servers are very sensitive to overheating and humidity, so temperature and
humidity must be closely controlled. Maintaining very precise target values
makes it possible to establish a climatic balance conducive to free cooling,
which allows energy savings.
Parameters to monitor Temperature (18 to 27-32°C) Hygrometry (and dew point temperature) Speed / Airflow Pressure
Our multifunctional sensors can simultaneously
measure and transmit all essential air parameters
with extreme precision: temperature, hygrometry,
speed, flow, and pressure, while calculating the
dew point temperature in real time.
Our Si-C320 can be equipped with hygrometry
probes with thermoregulated capacitive sensor,
Class A Pt100 temperature probes, or a self-
calibrated differential pressure sensor. This
provides the long-term, ongoing reliability and
accuracy required for server farm monitoring.
Climatic conditions also depend on good air
circulation in the server room. Air speed, flow and
pressure must be monitored at various key
locations via our transmitters connected to the
building's air management system.
Our hot wire probes provide industry-leading
accuracy and sensitivity to ensure proper air
distribution and avoid hot spots. The pressure
sensors ensure that the quantity of air in the
network is sufficient for the needs of the room.
Air flow rates must be controlled during supply
and extraction. The DBM 620 balometer is the
perfect instrument for any type of air inlet or
outlet, even for blowing floors, thanks to its
measuring grid system and its interchangeable
hoods.
Our portable devices allow all types of
measurement with great mobility to detect weak
points in the aeraulic system. Some
multifunctions like the AMI 310 use different
types of interchangeable probes for checks in the
environment, on the grid or in the duct, and on the
filters.
To ensure the safety and optimization of
installations by preventing any drift in
measurements, our technicians intervene on site
and establish calibration certificates and
verification reports ensuring the traceability of
measurements and preventing drift in sensors


SHSI / SHDI / SHDP : KIMO의 습도 측정 프로브는 온도와 습도를 측정하는 교체 가능한 프로브입니다. 측정 범위는 스테인리스 스틸 프로브의 경우 5 ~ 95 %RH 및 -40 ~ +180 °C이고, 폴리카보네이트 프로브의 경우 5 ~ 95 %RH 및 -20 ~ +80 °C 입니다.
Read More
SVS : KIMO의 열선 프로브는 스테인리스 스틸 재질의 풍속 및 온도 센서입니다. 측정 범위는 0~35 m/s, 0~50 °C, 0~99,999 m3/h입니다.
Read More
Si-PRO-DP : Si-C320 트랜스미터용 차압 모듈, 설치된 트랜스미터에 적용 가능, 외부 K타입 써머커플 사용(프로브 미포함) -10 ~ 50 °C 온도 보상 및 자동 교정 프로세스 클린룸, 제약/화장품 및 반도체 제조시설, 병원격리실, 수술실 등 중요한 환경에서의 차압 모니터링
Read More
KImo 휴대용 열선 풍속 풍량 측정 프로브 입니다.
Read More
최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다

최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다

최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다 최대 2줄까지 노출됩니다
적용사례 제목이 들어가는 자리입니다. 적용사례 제목이 들어가는 자리입니다.적용사례 제목이 들어가는 자리입니다. 적용사례 제목이 들어가는 자리입니다.적용사례 제목이 들어가는 자리입니다. 적용사례 제목이 들어가는 자리입니다.
Download적용사례 제목이 들어가는 자리입니다. 적용사례 제목이 들어가는 자리입니다.적용사례 제목이 들어가는 자리입니다. 적용사례 제목이 들어가는 자리입니다.적용사례 제목이 들어가는 자리입니다. 적용사례 제목이 들어가는 자리입니다.
Download적용사례 제목이 들어가는 자리입니다. 적용사례 제목이 들어가는 자리입니다.적용사례 제목이 들어가는 자리입니다. 적용사례 제목이 들어가는 자리입니다.적용사례 제목이 들어가는 자리입니다. 적용사례 제목이 들어가는 자리입니다.
Download